6.2 Making the Basic Settings of a Checker

6.2.1 Basic Flow of Checker Setting

Parameters vary depending on the checker due to a difference in inspection procedure of each checker.
Common setting procedure is described here.
Select a checker number first
1
and a checker.
2
Choose a memory.
For inspection of an extraction image
Setting of the
a
extraction color
For inspection of a gray image or binarized differential image
3
b
Setting of binary level
For inspection of a gray image or differential image
c
-
4
Set an area
5
Set the conditions per checker
6
Implement test
66
Specify a checker number between 1 and 99 and select
a checker.
Select a memory to inspect.
Specify the color to
Refer to the Use's Manual (Color
extract.
Extraction) for details of color extraction.
Upper and lower limits of binary level
You don't have to make any settings here.
Set an inspection area or "Mask" area,
which is not read partly, if necessary,
according to the inspection area.
Set the items of each checker.
Confirm whether inspection is performed
as expected or not
Page 67
Page 69
Page 70
Page 72
Refer to the appropriate
pages for each checker.
Refer to the appropriate
pages for each checker.