6.14.3 What To Do If You Faced a Trouble
Judgement result is always NG.
The following causes may be occurred.
• The object cannot be detected
Recheck and reconsider the area size and the detection conditions (Target, Max./Min. Area Limit,
Boundary Processing, etc.).
• No base position is registered.
The error code "E0049" may be displayed.
Since any base position is not registered, AX40 cannot work properly. Note that if you change area position,
size and shape after registering it, you need to register the base position again.
• Position Adjustment that refers to adjustment amount cannot detect the object.
If Position Adjustment is set to the numbers except "0", the adjustment amount of Position Adjustment or
Rotation Adjustment that is registered to the number is referred. If the Position Adjustment or Rotation
Adjustment checker cannot detect the object, the adjustment amount cannot be referred. Therefore, AX40
does not function properly and outputs "NG" result.