Changing Max. /Min. Numeric Calculation [%N]
This is a command to change max. and min. values by specifying a binary group from A to H. You can
change the max/min. limitations of numeric calculation of the product type currently selected by the
AX40.
Command Digit: "Valid"
Communication
Command / Description
direction
% N ?
Sending command
from external
device
??: 01 - 99 (Numeric calculation No.)
Min.: 11 (-2147483648 to 2147483647)
Max.: 11 (-2147483648 to 2147483647)
% N ?
Response: At
normal operation
(At the end of
??:01 - 99 (Numeric calculation No.)
setting)
Min.: 11 Fixed (11 Digit) (-2147483648 to 2147483647)
Max.: 11 Fixed (11 Digit) (-2147483648 to 2147483647)
Response: Error 1
Cause
Response: Error 2
ERROR signal is
output from the
Cause
parallel output port.
To specify the command digit ("valid/fixed (4 Digit)"), select "ENVIRONMENT" > "Serial Settings">
"Command Digit" from the menu bar.
236
?
,
Min.
?
,
Min.
% U CR
Command in the unspecified form or not provided was received.
Examples:
-
%N3, 1000, 25000
specified)
-
%B03, 1000, 25000
% Z CR
The max. value specified by a sending command is smaller than the min. value.
The max./min. binary level specified by a sending command are not within the settable
range.
,
Max.
CR
,
Max.
CR
C
(any other checker number than 01 to 99 was
R
C
(not provided command)
R