6.14.2 Registering a Base Position
The current object position can be registered as a base position in the following way. Before registering
the base position, check to make sure that the edges were detected by setting the horizontal/vertical
areas and performing a testing. When a live image is displayed, perform a test after importing a new
image. When a memory image is displayed, perform a test using the memory image currently displayed
without importing any images.
Registration Procedure:
1.
Select the "Base Position" tab.
The cursor moves to "Base Setting".
2.
Press the ENTER key.
When the dialog message shown below appears, choose "YES" to continue.
If the edges were correctly detected and the base position was registered, the following information
appears in the message area
In the Base Position tab
Adj. X: 0.0
Adj. Y: 0.0
Base Pos. X: Gravity coordinate X of the current object
Base Pos. Y: Gravity coordinate Y of the current object
Judgement: OK
Adj. X: 0.0
Adj. Y: 0.0
If the following message appears, it means horizontal and vertical edges were not detected. Check the
setting values of areas (positions of start /end points) or the inspection objects.
E0042 Base position cannot be detected.