Gray Edge- Reading Edge Threshold ([%H]) (For Gray edge checker)
Communication
Command / Description
Direction
% H ?
Sending
Command from
External Device
?? : 01 - 99(To specify an object checker No.)
Response- At
Serial setting - Command Digit: "Valid"
normal operation
% H ?
?? : 01 - 99 (Checker No.)
nnn: 001 - 255 (Edge threshold)
Serial setting - Command Digit: "Fixed (4 Digit)"
% H ?
?? : 01 - 99 (Checker No.)
nnnn: 0001 to 0255 or
nnnn
nnnn
% U CR
Response- Error 1
Cause
•
% Z CR
Response- Error 2
ERROR signal is
output from the
Cause
parallel output port.
•
•
? CR
?
,
n
n
n CR
?
n
n
n
n CR
1 to 255 (Edge threshold)
:0001 to 0255: If invalid digit = 0
:0001 to 0255: If invalid digit = space
Command in the unspecified form or not provided was received.
Examples:
C
-
%L1
(any other checker number than 01 - 08 was specified.)
R
C
-
%B01
(not provided command)
R
The checker type already created to the specified number is not the target checker of
this command.
No checker is created to the specified number.
229