11.1 Overview

Communication Mode
This is a communication mode to communicate with the external device via RS232C. The following three
communication modes are available. Communication contents differ depending on the mode. Select a
proper mode for your environment. Even if you choose any mode, most of the provided commands will
be available.
Communication Mode
Serial (Per Start)
Serial (Async.)
Computer Link
Communication specifications
Item
Communication Method
Synchronous Method
Communication Speed
Transmission Code
Transmission
Bit Length
Format
Stop Bit
Parity
Flow Control
Delimiter
218
Description
This is a 3-wire nonprocedural mode. In this mode, after inspection, the
following signals are not accepted until communication is complete.
This is a 3-wire nonprocedural mode. In this mode, after inspection, READY
signal is recovered while communication is established. After inspection
execution starts, the ready signal is recovered. Communication is established
when the AX40 does not perform image-processing tasks (when an image
import is executed while READY signal is on). READY signal OFF time
(Inspection Execution Time) is shorter than that for Serial (Per Start). (Refer to
page 209 for Timing Chart.)
Computer link supports a specific PLC. The AX40 writes inspection results to
the specific registers of PLC. Since the PLC automatically sends a response,
program for receiving data at the PLC side is not necessary. See page 241
Specification
Full duplex
Start-stop synchronization
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200-bit/s (Initial value:
9600)
ASCII
7-bit, 8-bit (Initial value: 8-bit)
1-bit, 2-bit (Initial value: 1-bit)
None/Odd/Even (Initial value: Odd)
None/Software (Initial value: None)
CR