9.2 Initial Settings

9.2.1 A list of Initial Setting Menu

Camera
Camera 1 (default)/
Camera 1+2
Memory 1
Color/ Gray/
Memory 2
Differential
(Initial value:
Memory 1 = Color
Memory 2 = Color)
Start
Once
(Initial value)
Repeat
Password
-
Password Request
On/ Off
(Initial value: Off)
Min. Ready OFF
0 to 1000 ms
Time (ms)
(Initial value: 0)
Language
English/ Japanese
To set the number of cameras used. Refer to page 49.
To select an image that is stored in either Memory 1 or Memory
2.
Refer to page 50 for details.
Inspection is performed by inputting external signals (parallel:
STA, serial: %S) from the external device.
After activating the device, start inspection without waiting input
signals from the external device. After finishing the first
inspection, start the second inspection and then repeat the
same operation. Inputting the signal "%S" for serial from the
external device enables the device to stop the inspection. In
such a case, the inspection restarts when the signals "STA" for
parallel or "%S" for serial is input from the external device.
This function allows only the persons that know the password
to change from RUN mode to SETUP mode. Refer to page 190
for details.
To set a minimum time for READY signal OFF. This function
will be helpful if the external device cannot detect the end of
inspection (the change from Off to On in READY signal) due to
fast processing speed and short ready off time. This function is
available for all the ready signals except the following listed
below.
SETUP mode
Communication with AXTOOL
All the menus and messages displayed on the screen monitor
can be displayed in English.