Panasonic MICRO-IMAGECHECKER AX40 User Manual page 223

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

Timing Chart: Area Display = No
1.
Specify a number of the target checker to re-register that is assigned to IN1-7
(Input the data more than 1 ms before FCT2 signal input).
2.
Make sure that READY signal is on and then input a FCT2 signal.
After READY signal is turned off, the template is re-registered.
3.
Make sure that READY signal is off and then turn the FCT2 signal off.
After re-registration is completed, READY signal is turned on.
You cannot re-register the templates of the following checkers by inputting a signal from the
external device.
- Position Adjustment (Matching)
- Rotation Adjustment (Matching)
- Rotation Adjustment (Contour)
If the image cannot be re-registered or the image has no features), ERROR signal will be
output.
If the external device cannot recognize that READY signal has been recovered (OFF > ON)
due to short product switch time, set Min. Ready Off time by selecting Menu bar >
ENVIRONMENT> Initial Settings in the menu bar.
215

Advertisement

Table of Contents
loading

Table of Contents