Panasonic MICRO-IMAGECHECKER AX40 User Manual page 146

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

6.20.2 Registering a Base Position
The setting procedure to register the base position of the object is as follows. Before registering a base
position, you can perform a test to check if Horizontal/Vertical Areas can detect an edge. When the image
currently displayed is a live image, import a new image and begin to test. When a Memory image is
displayed, test with the Memory image currently displayed without importing any images.
Registration Procedure:
1.
Highlight the "Base Position" tab.
The cursor moves to "Base Setting".
2.
Press the ENTER key.
When the dialog message "Register the base position?" appears, choose
"YES" to continue.
If the edges were correctly detected and the base position was registered, the
following data appear.
In the Base Position tab
Adj. X: 0.0
Adj. Y: 0.0
Base Pos. X: Middle point coordinate X of the highest correlation value
Base Pos. Y: Middle point coordinate Y of the highest correlation value
In the Message area
Judgement: OK
Adj. X: 0.0
Adj. Y: 0.0
If the following message appears, it means horizontal and vertical edges were not detected. Check the
setting values of areas (positions of start /end points) or the inspection objects.
E0042 Base position cannot be detected.
6.20.3 What To Do If You Faced a Trouble
Judgement result is always NG.
The following causes may be occurred.
• The object cannot be detected
Recheck and reconsider the template image, the settings of the search area size and the setting value of
the sequence.
• No base position is registered.
The error code "E0049" may be displayed.
Since any base position is not registered, AX40 cannot work properly. Note that if you do the followings
after registering it, you need to register the base position again.
• The memory you selected is set to extraction process
The error code "E0100" may be displayed.
The Position Adjustment (Matching) scans only a gray/differential image. Make sure that you do not
choose a memory that is set to extraction process.
• Position Adjustment that refers to adjustment amount cannot detect the object.
If Position Adjustment is set to the numbers except "0", the adjustment amount of Position Adjustment or
Rotation Adjustment that is registered to the number is referred. If the Position Adjustment or Rotation
Adjustment checker cannot detect the object, the adjustment amount cannot be referred. Therefore, AX40
does not function properly and outputs "NG" result.