10.2.2 Inspection Start-Repeat

Overview
If inspection start is set to "Repeat", inspection is started without waiting START signal (STA) input from
the external device after the device is activated. After the first inspection is completed and READY signal
is recovered, READY signal is turned off and inspection is executed without waiting the next START
signal input. To stop the inspection, send "%SCR "(a serial command) or press the A key for about one
second. If START signal is input again after the inspection stops, inspection is started and the inspection
is repeated.
Timing Chart
T1 > 1 ms
T2 = Inspection execution time or Minimum time for READY signal OFF. The times vary depending on
setting.
T3 = Min. 1 ms
1.
Make sure that READY signal is on and then input START signal for more than 1 ms.
2.
READY signal is turned off within 1 ms after START signal input. Then, image import starts.
3.
After the image import is completed, REND signal is turned on.
4.
After the program execution starts, judgement results D1 - D8 are output.
5.
After D1 - D8 are output, READY signal is recovered (OFF to ON) and REND signal is turned
off.
After that, inspection is repeated.
T2 time for READY signal OFF differs depending on the inspection condition.
If the minimum time of READY signal OFF is longer than the inspection execution time, T2 time will be the
minimum time for READY signal OFF.
Refer to "Starting Inspection-One time" for timing of result output.
210