11.3.4 Specifying a Parameter for COM Port

When making the settings of the COM port, follow the steps below. Be sure to specify the same
parameters for COM port that were used for the COM port setting for the communication destination and
PLC.
Item
Selections
Transmission
1200 to 115200 (Initial Value: 9600)
speed (bps)
Bit length
7 or 8 (Initial Value: 8)
Stop Bit
1 or 2 (Initial Value: 1)
Parity
None/Odd/Even (Initial value: Odd)
Flow Control
None/Software (Initial value: None)
Setting Procedure
1.
In SETUP mode, select "ENVIRONMENT" > "Serial Settings" from
the menu bar.
2.
Open the Port tab.
When PLC Model is set to "MELSEC FX", the setting values for the port are fixed.
Store "0" in the MELSEC FX register for specifying communication format.
Register for specifying communication format: D8120 (or D8420)