Data Monitor; Main Functions - Panasonic MICRO-IMAGECHECKER AX40 User Manual

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

7.5 Data Monitor

7.5.1 Main Functions

Displaying Data in RUN mode
Up to 50 of items including numeric calculation, judgement, statistics, and the current data monitor can
be displayed in table form during inspection (or in RUN mode). You can set to referenced data to display
or hide for each data.
The max. /min. values displayed in the data monitor can be changed on the screen.
Outputting Data to the External Device
Numeric calculation, statistics data and product number can be output to the external device. You can
choose Output /Not Output per data.
Setting Example
Type
1
Data
Min
A
150
110
B
1300
1000
The shaded cells of the items that have been set to
"Output" are displayed and the data are output from
the left upper cell to the right.
Max
Result
200
OK
2000
NG
Example of output results
Condition
Setting of Result Output - Digits of output: 5, Invalid
digits: Delete
Result
1,150,110,200,1300,1000,2000
Condition
Setting of Result Output - Digits of output = 4,
Invalid digits = Replacement with "0"
Result
0001015001100200130010002000
The empty cells and "Not Output" cells are skipped
and only the "Output" cells are consequently output.