System Reactions

4.1

System Reaction on SINUMERIK Alarms

Names
COMPBLOCKWITHREORG
Effect
Block preparation has detected an error, which can be rectified by modifying the pro-
gram. Reorganization is performed after a program modification.
− Correction block with reorganization.
Names
COMPENSATIONBLOCK
Effect
Block preparation has detected an error, which can be rectified by modifying the pro-
gram.
− Correction block
Names
FOLLOWUP
Effect
Follow-up of axes
− NC switches to follow-up mode
Names
INTERPRETER STOP
Effect
Program execution is aborted after all the prepared blocks (interpolator buffer) have
been processed.
− Interpreter stop
Names
LOCALREACTION
− Local alarm response
Effect
Names
NOALARMREACTION
− No alarm reaction
Effect
© Siemens AG 2009 All Rights Reserved