Siemens Sinumerik 840D sl Diagnostic Manual page 619

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
Switch to the machine area and change the program with the program correction function.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
120309
The selection is not possible. Please close the simulation and repeat the
selection.
Definitions:
The simulation is currently active in the program area.
A simultaneous editing is not possible.
Reaction:
Alarm display.
Remedy:
Close the simulation and make the selection again.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
120310
The selection is not possible. Please wait for the pending action or
terminate it, then repeat the selection.
Definitions:
In the program area, programs are currently being copied, loaded or unloaded.
A simultaneous editing is not possible.
Reaction:
Alarm display.
Remedy:
Wait until the action is completed or terminate the action via the softkey "Cancel", and then repeat the
selection.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
120400
The settings for the acyclic links with the drive units are not yet
effective.%nSwitch off/on HMI !
Definitions:
A file transfer from/to a drive unit has failed as the settings for acyclic links with the drive units become
effective only after an HMI reboot.
Reaction:
Alarm display.
Remedy:
Switch off/on HMI and then repeat the process leading to the alarm.
Program Con-
Internal
tinuation:
120401
SINAMICS: Write job for parameter %1, value %2, area %3: %4s timeout!
Parameters:
%1 = Number of parameter the value of which is to be written.
%2 = Value to be written
%3 = Area (drive object class to which the write job was addressed)
%4 = Time passed without the write job being acknowledged by the drive unit.
Definitions:
The write job of a SINAMICS parameter was not not acknowledged within 10 seconds by the drive
unit.
If the write job is not acknowledged within the next 10 seconds, the alarm will again be triggered.
The waiting period for the acknowledgement of a write job is a maximum of 130 seconds, i.e. if the
timeout specified in the alarm is 130 seconds, it is assumed that the write job has failed. Otherwise it
can be assumed that the write job was successful despite the timeout.
Reaction:
Alarm display.
Remedy:
As long as the timeout specified in the alarm is less than 130 seconds, acknowledge alarm, otherwise
switch off/on control, drive system and HMI, and then repeat the process leading to the alarm.
Program Con-
Internal
tinuation:
120402
Bus%1.Slave%2: %3: First commissioning of SINAMICS required!
Parameters:
%1 = Bus number
%2 = Slave address
%3 = Name of the affected drive unit
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
HMI-Alarms
2-619

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents