Overview of Alarms
HMI-Alarms
101204
SI data not confirmed
Definitions:
The SI data confirmation function was not executed because an error occurred during the processing.
Remedy:
--
101205
Drive data changed? -> Don't forget to save bootfiles!
Definitions:
When exiting the drive machine data images, the operator is reminded to save the boot files so that
drive machine data that may have been changed is not lost.
Remedy:
--
101206
Search operation in progress, please wait ...
Definitions:
The search function was initiated in the machine data images.
Remedy:
--
101207
Positioning to %1...
Parameters:
%1 = --
Definitions:
A list image, e.g. general machine data, has been selected.
The HMI is attempting to position at the last selected datum in this image.
Remedy:
--
101208
SI data are confirmed: axis %1
Parameters:
%1 = --
Definitions:
In the start-up area the function "Confirm Safety Integrated Data" has been started.
The message was output during this function in order to provied the user with an acknowledgement
regarding the operation of the function.
Remedy:
--
101209
SI data are confirmed: drive %1
Parameters:
%1 = --
Definitions:
In the start-up area the function "Confirm Safety Integrated Data" has been started.
The message was output during this function in order to provied the user with an acknowledgement
regarding the operation of the function.
Remedy:
--
101210
Machine data being prepared for display
Definitions:
A list image in the machine data was selected for which display options are active.
This image's machine data is individually checked to see whether it is permitted to be displayed.
Remedy:
--
101211
Address of NCK not changed!
Definitions:
An attempt was made to change the bus address of the NCK in the start-up area.
The change was rejected by the NCK; the reason is unknown.
Remedy:
--
101212
Address of NCK changed
Definitions:
The NCK's bus address was set to the specified value.
Remedy:
--
101213
Invalid NCK address!
Definitions:
The value specified for the new NCK bus address is too large.
Remedy:
--
101214
Initialization of this window unsuccessful!
Definitions:
An attempt was made to select the image of the NCK address in the start-up area.
An error occured while determining the nodes on the bus.
Due to inconsistent data, this image cannot be displayed.
Remedy:
--