Siemens Sinumerik 840D sl Diagnostic Manual page 125

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
10916
[Channel %1: ] Block %2 preparation problem in Look Ahead (module
%3, identifier %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Module identifier
%4 = Error code
Definitions:
The parameterized memory is inadequate to create an optimum path velocity profile. The profile cre-
ated is not as smooth as it could be.
Reaction:
Local alarm reaction.
Alarm display.
Warning display.
Remedy:
Change parameterization, increase IPO buffer.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
10930
[Channel %1: ] Block %2 interpolation type not allowed in stock removal
contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following types of interpolation are allowed in the contour program for stock removal: G00, G01,
G02, G03, CIP, CT
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the contour subroutine, program only path elements that consist of straight lines and arcs.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10931
[Channel %1: ] Block %2 incorrect stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following errors occurred in the subroutine for the contour during stock removal:
- Full circle
- Overlapping contour elements
- Wrong start position
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The errors listed above must be corrected in the subroutine for the stock removal contour.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10932
[Channel %1: ] Block %2 preparation of contour has been restarted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The first contour preparation/contour decoding run must be terminated with EXECUTE.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the keyword EXECUTE to terminate the contour preparation in the part program before again
calling up contour segmentation (keyword CONTPRON).
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-125

Hide quick links:

Advertisement

Table of Contents
loading