03/2009
Remedy:
Index == 1: The COA application is not executable in the current environment. Please inform the
authorized personnel/service department.
Index == 2 or.3: The memory requested by the COA application will not become available until after
another restart. This means that the alarm should no longer occur with a restart (NCK reset). Other-
wise, there is a real memory problem, and the COA application is not executable (see Index == 1).
Program Con-
Switch control OFF - ON.
tinuation:
7301
Assertion error in %1 line %2
Parameters:
%1 = File name
%2 = Line number
Definitions:
This alarm is purely a development alarm. It only occurs with externally linked COA applications.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is cancelled.
Remedy:
Query with COA developers
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7500
Block %1 invalid protection level for command %2 (protection level act.:
%3 prog.: %4)
Parameters:
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Definitions:
On assigning a protection level for a parts program command via REDEF command
- an impermissible parts program command has been programmed
- a protection level has been programmed that is logically smaller (larger in value) than the protection
level currently applicable for this command.
- the relevant definition file has not been protected sufficently against write access. The write protec-
tion of the file must be at least as high as the highest protection level that has been assigned to a parts
program command in this definition file.
Reaction:
Alarm display.
Remedy:
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UACCESS_DEF-
CESS_ DEF. Please see the Siemens Programming Guide or the OEM documentation for the lan-
guage commands permissible for the relevant system configurations.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8000
[Channel %1: ] Option 'Interrupt routines' not set
Parameters:
%1 = Channel number
Definitions:
Fast NCK inputs are required for the input signals in order to activate the interrupt routines and rapid
lift from contour. This function is not included in the basic version and must be retrofitted when needed.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Do not use rapid interrupt inputs or con-
tact the machine manufacturer with a view to retrofitting this option!
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8010
Option 'activation of more than %1 axes' not set
Parameters:
%1 = Number of axes
© Siemens AG, 2009. All Rights Reserved