Remedy:
Please inform the authorized personnel/service department.
For retrofitting the option, please refer to your machine manufacturer or to a sales representative of
SIEMENS AG, A&D MC.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
8041
Axis %1: MD %2 reset, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Definitions:
All of the axes selected in the machine data of the assigned option are used. Safety functions have
been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
--
Program Con-
Switch control OFF - ON.
tinuation:
8044
Option for IPO cycle time %1 ms not set
Parameters:
%1 = Impermissible IPO cycle time
Definitions:
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
- Option-free >= 8ms
- 1. 1st step >= 6ms
- 2. 2nd step >= 4ms
- 3. 3rd step >= 2ms
- 4. 4th step <2ms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Increase IPO cycle time (e.g. via MD10070 $MN_IPO_SYSCLOCK_TIME_RATIO)
Program Con-
Switch control OFF - ON.
tinuation:
8050
Option 'SPL inputs/outputs' not set.
Definitions:
The number of PLC I/Os has not been set in the option date for Solution Line.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select area SI Basic or SI Comfort in the option date.
Program Con-
Switch control OFF - ON.
tinuation:
8051
Option 'Handwheel on PROFIBUS' not set
Definitions:
The option to operate handwheels on PROFIBUS is not set.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Activate option 'Handwheel on PROFIBUS'
Program Con-
Switch control OFF - ON.