03/2009
61301
[Channel %1: ] Block %2: Probe not switching
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring distance was completely traversed, but no switching signal was generated at the mea-
suring input.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
-Check measuring input.
-Check measuring distance.
-Probe defective.
61302
[Channel %1: ] Block %2: Probe - collision
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring probe collided with an obstacle when being positioned.
Alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
- Check spigot diameter (may be too small)
- Check measuring distance (may be too long)
61303
[Channel %1: ] Block %2: Safety margin exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring result differs greatly from the specified value.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
- Check setpoint value and parameter _TSA
61304
[Channel %1: ] Block %2: Allowance
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61305
[Channel %1: ] Block %2: Dimension too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61306
[Channel %1: ] Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE982, CYCLE994.
Remedy:
- Check setpoint value and parameter _TDIF
61307
[Channel %1: ] Block %2: Incorrect measuring variant
Parameters:
%1 = Channel number
%2 = Block number, label channel number