Overview of Alarms
NCK alarms
75061
[Channel %1: ] MCSC: MD modification on active coupling axis %2
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
Machine data MD 63000 CC_MASTER_AXIS has been changed when the coupling was active.
Reaction:
Alarm display.
NC Stop on alarm.
Remedy:
Reset machine data to its old value, switch off the coupling and then enter the new value.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75062
[Channel %1: ] MCSC: axes to be coupled are not in standstill axis %2
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The CC_Master and/or CC_Slave axes were not at standstill when the coupling was switched on.
Reaction:
Alarm display.
NC Stop on alarm.
Remedy:
Input G601 for path axes or program a stop preprocessor (STOPRE) before coupling with
CC_COPON.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75070
[Channel %1: ] MCSC: wrong machine data for collision protection axis
%2
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
Incorrect machine data for collision protection.
Reaction:
Interpreter stop
Alarm display.
Remedy:
Correct machine data. The axes must be either both rotary axes or both linear axes!
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75071
[Channel %1: ] MCSC: collision monitoring axis %2
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The collision monitor has responded because the deceleration precomputation has detected that the
distance between the axes has fallen below the configured distance.
Reaction:
Alarm display.
NC Stop on alarm.
Remedy:
Traverse the axis out of the danger area in manual mode.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
75090
Axis %1 stopped by external process monitoring system
Parameters:
%1 = Axis number
Definitions:
An external process monitoring system has stopped the axis, as tool breakage is to be expected or
has already occured.
Reaction:
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change current tool, if required.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
2-550
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links: