Siemens Sinumerik 840D sl Diagnostic Manual page 127

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Definitions:
Insufficient free dynamic memory during curve table definition.
The object type parameter specifies for which curve table object
the memory will not suffice:
1: Number of curve tables too small (MD18400 $MN_MM_NUM_CURVE_TABS)
2: Number of linear curve table segments too small (MD18403 $MN_MM_NUM_CURVE_SEG_LIN)
3: Number of polynomial curve table segments too small (MD18402
$MN_MM_NUM_CURVE_SEGMENTS)
4: Number of curve table polynomials too small (MD18404 $MN_MM_NUM_CURVE_POLYNOMS)
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel / service department. Delete curve tables that are no longer
required, or reconfigure the memory space for the curve tables. The curve table definition process
now has to be repeated; see machine data:
MD18400 $MN_MM_NUM_CURVE_TABS, MD18402 $MN_MM_NUM_CURVE_SEGMENTS,
MD18403 $MN_MM_NUM_CURVE_SEG_LIN,
MD 18404 $MN_MM_NUM_CURVE_POLYNOMS.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10942
[Channel %1: ] Block %2 curve table %3: illegal instruction during
definition
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
Various illegal command sequences cause the output of this alarm during the definition of the curve
table. For example, it is impermissible to terminate definition of a curve table with M30 before program-
ming the CTABEND command.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10943
[Channel %1: ] Block %2 curve table %3: direction reversal of lead value
in the block not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
The conditions for converting a programmed contour to a curve table were not fulfilled in this block.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10944
[Channel %1: ] Block %2 curve table %3: illegal transformation
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
It is impermissible to use a transformation in a curve table if the leading axis or following axis pro-
grammed in CTABDEF is involved in the transformation. Exception: TRAANG.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-127