NCK alarms
61367
[Channel %1: ] Block %2: Parameters _SETV[0...3] or _SETV[4...7] are
identical
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Remedy:
Specify different positions for the relevant points of _SETV[0...7] .
61368
[Channel %1: ] Block %2: Straights through parameter _SETV[0...3] or
_SETV[4...7]do not intersect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Remedy:
Specify different positions for the relevant points of _SETV[0...7] .
61369
[Channel %1: ] Block %2: Position of corner not clearly definable, check
parameter _SETV[0...7]
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define P1 and P2 or P3 and P4 in a way that the intersection of the straights determined by these
points is outside the sections formed by P1 and P2 or P3 and P4.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61370
[Channel %1: ] Block %2: _PROTVAL[0] -_PROTVAL[5] do not have any
entries
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Remedy:
Enter values in _PROTVAL[0...5].
61371
[Channel %1: ] Block %2: Product of column width and number of
columns exceeds 200 characters per line
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Remedy:
Reduce the column width (_PROTFORM[4]) or number of columns (_PROTVAL[2...5]).
61372
[Channel %1: ] Block %2: selected meas.variant requires SPOS-capable
spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Change measuring variant or check machine equipment.
61373
[Channel %1: ] Block %2: Mono-directional probe requires SPOS-capable
spindle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check machine equipment.
2-504