Siemens Sinumerik 840D sl Diagnostic Manual page 238

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
15300
[Channel %1: ] Block %2 invalid number-of-passed-blocks during block
search
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the function "Block search with calculation" a negative number of passes has been entered in col-
umn P (number of passes). The permissible range of values is P 1 - P 9 999.
Reaction:
Alarm display.
Remedy:
Enter only positive number of passes within the range of values.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15310
[Channel %1: ] Block %2 file requested during block search is not
available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During block search, a target has been specified with a program that has not been loaded.
Reaction:
Alarm display.
Remedy:
Correct the specified search target accordingly or reload the file.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15320
[Channel %1: ] Block %2 invalid block search command
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in
column type of the block search window. The following block search orders are allowed.
Type Meaning
1 Search for block number
2 Search for label
3 Search for string
4 Search for program name
5 Search for line number in a file
Reaction:
Alarm display.
Remedy:
Modify the block search command.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15330
[Channel %1: ] Block %2 invalid block number as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! Positive integers are allowed as block numbers. Block numbers must be preceded by ":"
and subblocks by an "N".
Reaction:
Alarm display.
Remedy:
Repeat the input with corrected block number.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15340
[Channel %1: ] Block %2 invalid label as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! A label must have at least 2 but no more than 32 characters, and the first two characters
must be alphabetic or underscore characters. Labels must be concluded with a colon.
Reaction:
Alarm display.
Remedy:
Repeat the input with corrected label.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
2-238
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved