Siemens Sinumerik 840D sl Diagnostic Manual page 624

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
HMI-Alarms
Definitions:
The ITS server has not yet been initialized, it cannot, therefore, execute the order.
Remedy:
Execute your operation again later.
129941
Not all involved channels are in RESET.
Definitions:
At least one of the channels configured in the workpiece for time measuring is not in the "Reset" state.
Remedy:
Ensure that all channels configured in the workpiece for time measurement are in the "Reset" state.
129942
Not all involved channels are in AUTO.
Definitions:
At least one channel/mode group configured in the workpiece for time measurement is not in the
"AUTO" mode.
Remedy:
Ensure that all channels/mode groups configured in the workpiece for time measurement are in the
"AUTO" state.
129943
%1: Invalid configuration of $AN_TIMER.
Parameters:
%1 = NCU name
Definitions:
Setting AN_TIMER_Nr of section [DAT] in ITS.INI is incompatible with the setting in machine data
18710 $MN_MM_NUM_AN_TIMER.
Remedy:
The value in general machine data 18710 $MN_MM_NUM_AN_TIMER must be at least "1".
The value set for AN_TIMER_Nr of section [DAT] in ITS.INI must be higher than "0" and smaller than
or equal to the value of general machine data 18710 $MN_MM_NUM_AN_TIMER.
The following rule applies:
0 < AN_TIMER_Nr <= $MN_MM_NUM_AN_TIMER
129944
%1: $AN_TIMER[%2] not running.
Parameters:
%1 = NCU name
%2 = Index of system variable $AN_TIMER used.
Definitions:
The $AN_TIMER[AN_TIMER_No] configured with setting AN_TIMER_Nr of section [DAT] in ITS.INI
has not been started.
Remedy:
Ensure that system variable $AN_TIMER[AN_TIMER_No] with value "0" is initialized and started on
NCU ramp-up; for example, with AN_TIMER_No = 1 the system variable must be initialized with NC
instruction $AN_TIMER[1] = 0.
129945
%1: The current NCK version (%2) is too old for this type of time
measuring.
Parameters:
%1 = NCU name
%2 = NCK software version of NCU %1.
Definitions:
Measuring method "1" configured with setting MeasureMode of section [DAT] in ITS.INI cannot be
used, as the current NCK version is too old.
Remedy:
Either upgrade NCK software to at least 511300 or select measuring method "0".
129946
General error. See entry in log file ITSx.LOG.
Definitions:
A general error has occured that is specified in detail in log file "ITSx.LOG".
The files are stored in sub-directory "SEditor" of the "TMP" directory in HMI Advanced.
Remedy:
Follow the instructions in log file "ITSx.LOG" or contact the Siemens hotline.
142000
Operator at the machine is waiting for support via remote diagnostics!
%1 %2 %3 %4
Parameters:
%1 = IP address for existing Internet connection via modem
Definitions:
Will be triggered in "User Controlled" mode, if user uses "Request Support" function.
Reaction:
Alarm display.
Remedy:
Acknowledge alarm
Program Con-
Internal
tinuation:
142001
Operator at the machine is waiting for support via remote diagnostics!
%1 %2 %3 %4
Parameters:
%1 = IP address for existing Internet connection via modem
Definitions:
Will be triggered in "User Controlled" mode, if user uses "Request Support" function.
Reaction:
Alarm display.
Remedy:
Acknowledge alarm
2-624