Siemens Sinumerik 840D sl Diagnostic Manual page 314

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
18100
[Channel %1: ] Block %2 invalid value assigned to FXS[]
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following values are valid at the present time:
0: "Deselect traverse against fixed stop"
1: "Select traverse against fixed stop" valid.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
--
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18101
[Channel %1: ] Block %2 invalid value assigned to FXST[]
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only the range 0.0 - 100.0 is valid at the present time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
--
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18102
[Channel %1: ] Block %2 invalid value assigned to FXSW[]
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only positive values including zero are valid at the present time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
--
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
18200
[Channel %1: ] Block %2 curve table: block search stop not allowed with
definition CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Program instructions that lead to a preprocessing stop are not allowed within a curve table definition.
The system variable $P_CTABDEF can be queried to check whether a table definition is currently
active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Put the block in parenthesis using "IF NOT($P_CTABDEF) ... ENDIF" or remove the instruction that
causes the preprocessing stop. Then start the part program again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18201
[Channel %1: ] Block %2 curve table: table %3 does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
2-314
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading