4610
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Definitions:
For SINUMERIK 840D and SINUMERIK 840DI only:
The handwheel module for handwheel %1 requested through MD11351
$MN_HANDWHEEL_MODULE is not available for 840D systems. An 840D system is always
regarded as a module. Therefore MD11351 $MN_HANDWHEEL_MODULE = 1 must always be set
for handwheels directly linked to 840D systems.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date MD11351 $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program Con-
Switch control OFF - ON.
tinuation:
4611
Invalid handwheel input for handwheel %1
Parameters:
%1 = Handwheel input
Definitions:
For SINUMERIK 840D and SINUMERIK 840Di only:
The handwheel input for handwheel %1 requested through MD11352 $MN_HANDWHEEL_INPUT is
not available for 840D systems. A maximum of 2 or 3 handwheels can be linked directly to 840D sys-
tems:
840D powerline: 1st and 2nd handwheels directly to the 840D hardware
840Di: 1st and 2nd handwheels directly to the extension board
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure MD11352 $MN_HANDWHEEL_INPUT for a valid input for the corresponding handwheel
Program Con-
Switch control OFF - ON.
tinuation:
4620
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Definitions:
For SINUMERIK 802D only:
The handwheel module for handwheel %1 requested through MD11351
$MN_HANDWHEEL_MODULE is not available for 802D systems. An 802D system is always
regarded as a module. Therefore MD11351 $MN_HANDWHEEL_MODULE = 1 must always be set
for handwheels linked directly to 802D systems.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date MD11351 $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program Con-
Switch control OFF - ON.
tinuation:
4621
Invalid handwheel input for handwheel %1
Parameters:
%1 = Handwheel input
Definitions:
For SINUMERIK 802D only:
The handwheel input for handwheel %1 requested through MD11352 $MN_HANDWHEEL_INPUT is
not available for 802D systems. A maximum of 2 handwheels can be directly linked to 802D system.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure MD11352 $MN_HANDWHEEL_INPUT for a valid input for the corresponding handwheel
Program Con-
Switch control OFF - ON.
tinuation: