Siemens Sinumerik 840D sl Diagnostic Manual page 45

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
4260
Machine data %1 illegal
Parameters:
%1 = String: MD identifier
Definitions:
The selected cam pair was not activated by MD10450 $MN_SW_CAM_ASSIGN_TAB, or several cam
pairs were selected.
Reaction:
Mode group not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Activate the cam pair or select only one cam pair.
Program Con-
Switch control OFF - ON.
tinuation:
4270
Machine data %1 assigns not activated NCK input/output byte %2
Parameters:
%1 = String: MD identifier
%2 = Index
Definitions:
The specified machine data assigns a digital input/output byte or an analog input/output signal the pro-
cessing of which has not been activated to an NC function.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Correct machine data. Activate required inputs/outputs via MDs:
MD10350 $MN_FASTIO_DIG_NUM_INPUTS
MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS
MD10300 $MN_FASTIO_ANA_NUM_INPUTS
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
Activation of fast inputs/outputs does not require the corresponding hardware configuration to be
available at the control. All functions using fast inputs/outputs can also be made use of by the PLC
specification/modification defined in the VDI interface, if the response time requirements are reduced
accordingly.
Activated inputs/outputs increase the computation time requirement of the interpolation cycle because
the PLC manipulation signals are handled cyclically. Note: Deactivate any inputs/outputs not in use.
Program Con-
Switch control OFF - ON.
tinuation:
4275
Machine data %1 and %2 both assign the same NCK output byte no. %3
several times
Parameters:
%1 = String: MD identifier
%2 = String: MD identifier
%3 = No. of output
Definitions:
The specified machine data assign two NC functions to the same digital/analog output.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct machine data.
Program Con-
Switch control OFF - ON.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents