0x57: Action: All slave DOs at ON - error: Master not in state 0x62.
0x62: Action: All slave-DOs at OFF - error: State of DI 20...23 does not correspond to the expected
state (0V) or the master not in state 0x6D.
0x6D: Action: All slave DOs at OFF - error: Master not in state 0x78.
0x78: Action: All slave-DOs at ON - error: State of DI 20...23 does not correspond to the expected
state (0V) or the master not in state 0x83.
0x83: Action: All slave DOs at ON - error: Master not in state 0x8E.
0x8E: Action: All slave-DOs at OFF - error: State of DI 20...23 does not correspond to the expected
state (0V) or the master not in state 0x99.
0x99: Action: All slave DOs at OFF - error: Master not in state 0xA4.
0xA4: Action: All slave-DOs at OFF - error: State of DI 20...23 do not correspond to the expected state
24V) or the master not in state 0xAF.
0xAF: Action: All slave DOs at the original state - error: Master not in state 0xBA.
0xBA: Action: All slave DOs at the original state - error: Master not in state 0xC5.
0xC5: Action: Return to start state, test stop completed on the slave side. Error: Master not in state
0xD0.
Test stop step cc for master (hexadecimal):
0x0A: No actions - error: Slave not in initial state 0x00.
0x15: No actions - error: Slave not in initial state 0x0A.
0x20: No actions - error: F-DIs 0...4 of the slave do not correspond with those of the master (expected:
level 0) or slave not in state 0x15.
0x2B: No actions - error: Slave not in initial state 0x20.
0x36: No actions - error: F-DIs 0...5 of the slave do not correspond with those of the master (expected:
level 0) or slave not in state 0x2B.
0x41: Action: All master DOs at OFF - error: Slave not in state 0x36.
0x4C: Action: All master DOs at OFF - error: Slave not in state 0x41.
0x57: Action: All master-DOs at ON - error: State of DI 20...23 of the slave does not correspond to the
expected state (24V) or the slave not in state 0x4C.
0x62: Action: All master DOs at ON - error: Slave not in initial state 0x57.
0x6D: Action: All master-DOs at ON - error: State of DI 20...23 of the slave does not correspond to the
expected state (0V) or the slave not in state 0x62.
0x78: Action: All master DOs at ON - error: Slave not in state 0x6D.
0x83: Action: All master-DOs at OFF - error: State of DI 20...23 of the slave does not correspond to
the expected state (0V) or the slave not in state 0x78.
0x8E: Action: All master DOs at OFF - error: Slave not in state 0x83.
0x99: Action: All master-DOs at OFF - error: State of DI 20...23 of the slave does not correspond to
the expected state (0V) or the slave not in state 0x8E.
0xA4: Action: All master DOs at OFF - error: Slave not in state 0x99.
0xAF: Action: All master-DOs at OFF - error: Status of DI 20...23 of the slave does not correspond to
the expected state (24V) or the slave not in state 0xA4.
0xBA: Action: All master DOs at the original state - error: Slave not in state 0xAF.
0xC5: Action: All master DOs at the original state - error: Slave not in state 0xBA.
0xD0: Wait for the end of the test stop and return to the start state
Note: A check of the switching state of the F-DIs and DIs always refers to the switching operation of
the previous state. The actions in one state are always only carried out after the actual state has been
checked.
Remedy:
Check the wiring of the F-DIs and F-DOs and restart the test stop. The fault is withdrawn if the test
stop is successfully completed.
235014
<location>TM54F: Test stop required
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
- after powering up the drive, a test stop has still not been carried out.
- a new test stop is required after commissioning.
- the time to carry out the forced checking procedure (test stop) has expired (p10003).
Remedy:
Initiate test stop (BI: p10007).