Siemens Sinumerik 840D sl Diagnostic Manual page 544

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
62312
[Channel %1: ] Block %2: probe is not perpendicular to plane!
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction:
Alarm display.
Remedy:
--
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
62313
[Channel %1: ] Block %2: The number of lines per page _PROTFORM[0]
is incorrect and is automatically adjusted.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycle: CYCLE106.
Remedy:
Check _PROTFORM[0] in the program.
62314
[Channel %1: ] Block %2: Traverse path limitation via software end
position, collision detection activated, continue with NC START / cancel
with RESET.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE977
Remedy:
Position the workpiece to be measured further away from the software end positions.
62315
[Channel %1: ] Block %2: Overwrite swivel data record TCARR = %4, yes
-> NC start, no -> reset
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE996
Remedy:
62316
[Channel %1: ] Block %2: Overwrite TRAORIdata, yes -> NC start, no ->
reset
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE996
Remedy:
62317
[Channel %1: ] Block %2: Tolerance of the linear vector %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE996
Remedy:
62318
[Channel %1: ] Block %2: Tolerance of the rotary axis vector %4
exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE996
Remedy:
62335
[Channel %1: ] Block %2: No internal correction of the calibration data
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by the following cycles: CYCLE961, CYCLE977, CYCLE978, CYCLE979,
CYCLE996, CYCLE997, CYCLE998
2-544
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents