Siemens Sinumerik 840D sl Diagnostic Manual page 155

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
- Correct the name used (writing error)
- $TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx,
$TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10
- These are the OEM parameters of the tools magazines, The corresponding machine data value is
set to < 10, or the option 'TM OEM parameters' has not been set.
- Use correct parameter number, or - if the name cannot be changed - set machine data correction
(see MD18096 $MN_MM_NUM_CC_TOA_PARAM, ... MD18206
$MN_MM_NUM_CCS_TOA_PARAM, ...). )
- Check the option (machine data are only effective when the option is enabled).
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12553
[Channel %1: ] Block %2 name %3 option/function is not active
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The option (if MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 1) or the NC function (if
MD10711 $MN_NC_LANGUAGE_CONFIGURATION = 3)
related to this language command is not active.
But the name of the language command is known.
Each programming of this language command is rejected with this alarm.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the "Compensation block" function by pressing the PROGRAM
CORRECT softkey. The cursor positions itself on the incorrect block.
- Correct the name used (in the case of a typing error).
- Activate the NC function (if a language command of an inactive function has been programmed).
- Enable the option required (if a language command of a function with a non-enabled option has been
programmed).
See also MD10711 $MN_NC_LANGUAGE_CONFIGURATION.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12554
[Channel %1: ] Block %2 replacement cycle %3 for the predefined
procedure is missing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cycle name
Definitions:
The replacement cycle that is to be called instead of the predefined procedure
is not present / unknown in the control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the PROGRAM
CORRECT softkey. The cursor will position itself in the faulty block.
- Correct the name used for the predefined procedure (write error)
- Or load the replacement cycle into one of the cycle directories (+ restart)
- Or set the machine data bit for the predefined procedure in MD11754
$MN_COUPLE_CYCLE_MASK to 0 so that the predefined procedure is executed again.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12555
[Channel %1: ] Block %2 function not available (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions:
The identifier has not been defined for this system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
© Siemens AG, 2009. All Rights Reserved