Overview of Alarms
NCK alarms
Program Con-
Switch control OFF - ON.
tinuation:
27093
Checksum error NCK-SPL, %1, %2, %3
Parameters:
%1 = Extension indicating the type of error
%2 = Extension indicating the reference variable
%3 = Extension indicating the actual variable
Definitions:
A checksum error has occurred in the NCK SPL. The file /_N_CST_DIR/_N_SAFE_SPF was subse-
quently modified. The safe programmable logic (SPL) in the NCK may be corrupted. Parameter %1
indicates the type of modification:
- %1 = FILE_LENGTH: the file length has changed.
- %1 = FILE_CONTENT: the file contents have changed.
%2 specifies the reference variable (file length, checksum of file contents), %3 specifies the actual
variable which is calculated cyclically.
Reaction:
Alarm display.
Remedy:
Check the file and the time of the last modification to the file. Reload the original file and start the mon-
itoring system again with a Power On.
Program Con-
Switch control OFF - ON.
tinuation:
27094
Write access to system variable %1 only allowed from NCK-SPL
Parameters:
%1 = Name of safety system variable concerned
Definitions:
Write access to a safety system variable is only allowed from the part program
/_N_CST_DIR/_N_SAFE_SPF. If this error occurs, an instruction from another part program was
detected.
Reaction:
Alarm display.
Remedy:
Check the part programs you are using for write accesses to safety system variables.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
27095
%1 SPL protection not activated
Parameters:
%1 = Name of the component on which the protection is not activated (NCK or PLC)
Definitions:
The protection features are not activated for the SPL. The startup phase of the SPL is not yet com-
plete. No stop reaction (Stop D or E) was initiated on an error in data cross-comparison between NCK
and PLC.
Reaction:
Alarm display.
Remedy:
- Remedy for NCK: Activate the protection features with MD $MN_PREVENT_SYNACT_LOCK[0,1].
The number range of the synchronized action IDs used in the SPL must be entered in this MD.
- Remedy for PLC: Activate the protection features by setting the appropriate data bit in DB18.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
27096
SPL start not allowed
Definitions:
To start the SPL in protected state (MD $MN_PREVENT_SYNACT_LOCK[0,1] not equal 0) Safety
Integrated functionality must first be activated for at least one axis (via MD
$MA_SAFE_FUNCTION_ENABLE). Without this functionality it is only possible to operate SPL in
start-up state.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Start up axial Safety Integrated functionality or remove the SPL protection via MD
$MN_PREVENT_SYNACT_LOCK[0,1].
Program Con-