Siemens Sinumerik 840D sl Diagnostic Manual page 671

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
201511
<location>BICO: Interconnection between different normalizations
Message
Parameter: %1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The requested interconnection was established. However, a conversion is made between the BICO
output and BICO input using the reference values.
- the BICO output has different normalized units than the BICO input.
- message only for interconnections within a drive object.
Example:
The BICO output has, as normalized unit, voltage and the BICO input has current.
This means that the factor p2002 (contains the reference value for current) / p2001 (contains the ref-
erence value for voltage) is calculated between the BICO output and BICO input.
Fault value (r0949, interpret decimal):
Parameter number of the BICO input (signal sink).
Remedy:
No correction needed.
201512
<location>BICO: No normalization available
Message
%1
value:
Drive object:
All objects
Reaction:
A_INFEED: OFF2 (OFF1)
SERVO: OFF2
VECTOR: OFF2
Acknowledge:
POWER ON
Cause:
An attempt was made to determine a conversion factor for a normalization that does not exist.
Fault value (r0949, interpret decimal):
Unit (e.g. corresponding to SPEED) for which an attempt was made to determine a factor.
Remedy:
Apply normalization or check the transfer value.
201513
<location>BICO: Spanning DO between different normalizations
Message
Parameter: %1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The requested interconnection was established. However, a conversion is made between the BICO
output and BICO input using the reference values.
An interconnection is made between different drive objects and the BICO output has different normal-
ized units than the BICO input or the normalized units are the same but the reference values are dif-
ferent.
Example:
The BICO output has, as standard unit, voltage and the BICO input has current; both lie in different
drive objects.
This means that the factor p2002 (contains the reference value for current) / p2001 (contains the ref-
erence value for voltage) is calculated between the BICO output and BICO input.
Fault value (r0949, interpret decimal):
Parameter number of the BICO input (signal sink).
Remedy:
None necessary.
201514
<location>BICO: Error when writing during a reconnect
Message
Parameter: %1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
SINAMICS-Alarms
2-671