Siemens Sinumerik 840D sl Diagnostic Manual page 992

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
SINAMICS-Alarms
249155
<location>Cooling system: Power Stack Adapter, firmware version too
old
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, VECTOR
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
The firmware version in the Power Stack Adapter (PSA) is too old and does not support the liquid cool-
ing.
Remedy:
Upgrade the firmware. Check EEPROM data.
249156
<location>Cooling system: Cooling liquid temperature has exceeded the
fault threshold
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, VECTOR
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The cooling liquid intake temperature has exceeded the permanently set fault threshold.
Remedy:
Check the cooling system and the ambient conditions.
249170
<location>Cooling system: Alarm has occurred
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The cooling system signals a general alarm.
Remedy:
- check the wiring between the cooling system and the input terminal (Terminal Module).
- check the external control device for the cooling system.
249171
<location>Cooling system: Conductivity has exceeded the alarm
threshold
Message
-
value:
Drive object:
A_INF, B_INF, S_INF, SERVO
Reaction:
NONE
Acknowledge:
NONE
Cause:
The conductivity of the cooling liquid has exceeded the selected alarm threshold (p0269[1]).
See also: p0261 (Cooling system, starting time 2), p0262 (Cooling system, fault conductivity delay
time), p0266 (Cooling system, feedback signals, signal source)
Remedy:
Check the device to de-ionize the cooling liquid.
249171
<location>Cooling system: Conductivity has exceeded the alarm
threshold
Message
-
value:
Drive object:
VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The conductivity monitoring of the cooling liquid is set (r0267 bit 7, from p0266 index 7).
See also: p0261, p0262, p0266, r0267
Remedy:
Check the device to de-ionize the cooling liquid.
2-992
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG 2009 All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading