<location>Encoder 3: Position actual value preprocessing does not have
a valid encoder
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The following problem has occurred during the position actual value preprocessing.
- an encoder data set has been assigned, however, the encoder data set does not contain any
encoder data (p0400 = 0) or invalid data (e.g. p0408 = 0).
Remedy:
Check the drive data sets, encoder data sets.
See also: p0187, p0188, p0189, p0400, p2502
207590
<location>Encoder 1: Drive Data Set changeover in operation
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
A Drive Data Set changeover (DDS) with a change of the mechanical relationships and the encoder
assignment (p2502) was requested in operation.
Remedy:
To changeover the drive data set, initially, exit the "operation" mode.
207591
<location>Encoder 2: Drive Data Set changeover in operation
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
A Drive Data Set changeover (DDS) with a change of the mechanical relationships and the encoder
assignment (p2502) was requested in operation.
Remedy:
To changeover the drive data set, initially, exit the "operation" mode.
207592
<location>Encoder 3: Drive Data Set changeover in operation
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
A Drive Data Set changeover (DDS) with a change of the mechanical relationships and the encoder
assignment (p2502) was requested in operation.
Remedy:
To changeover the drive data set, initially, exit the "operation" mode.
207593
<location>Encoder 1: Value range for position actual value exceeded
Message
%1
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The value range (-2147483648 ... 2147483647) for the position actual value representation was
exceeded.
When the overflow occurs, the "referenced" or "adjustment absolute measuring system" status is
reset.