Siemens Sinumerik 840D sl Diagnostic Manual page 456

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
Definitions:
No tool (T) has been programmed before the cycle call. Alarm triggered by following cycles:
CYCLE71, CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program tool (T).
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61010
[Channel %1: ] Block %2: Finishing allowance too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The finishing allowance for the base is greater than the total depth. Alarm triggered by following cycle:
CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce finishing allowance.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61011
[Channel %1: ] Block %2: Scaling not permissible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A scale factor is active which is illegal for this cycle. Alarm triggered by following cycles: CYCLE71,
CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify scale factor.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61012
[Channel %1: ] Block %2: Different scaling in planes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64, CYCLE76, CYCLE77.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61013
[Channel %1: ] Block %2: Basic settings were changed, program cannot
be executed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The basic settings are not compatible with the generated program. Alarm triggered by following
cycles: E_CP_CE, E_CP_CO, E_CP_DR, F_CP_CE, F_CP_CO, F_CP_DR.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check and, if necessary, change the basic settings.