Siemens Sinumerik 840D sl Diagnostic Manual page 463

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61115
[Channel %1: ] Block %2: Approach or retract mode(straight / circle /
plane / space) incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The approach or retract mode to/from the contour has been incorrectly defined. Alarm triggered by
following cycle: CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter _AS1 or _AS2.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61116
[Channel %1: ] Block %2: Approach or retract path = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The approach or retract path has been specified with zero. Alarm triggered by following cycle:
CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter _LP1 or _LP2.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61117
[Channel %1: ] Block %2: Active tool radius <= 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The radius of the active tool is negative or zero. Alarm is triggered by the following cycles: CYCLE63,
CYCLE71, POCKET3, POCKET4.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify radius.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61118
[Channel %1: ] Block %2: Length or width = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The length or width of the milling area is illegal. Alarm triggered by following cycle: CYCLE71.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameters _LENG and _WID.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61119
[Channel %1: ] Block %2: Nominal or core diameter programmed
incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
© Siemens AG, 2009. All Rights Reserved