Siemens Sinumerik 840D sl Diagnostic Manual page 167

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
14006
[Channel %1: ] Block %2 invalid program name %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
When selecting or calling an NC program it was found that the program name did not follow NC con-
ventions:
- The length of the program name, without prefix _N_ and Suffix _MPF / _SPF, must not exceed 24
characters, as otherwise the program name is truncated in the OPI variables.
Reaction:
Alarm display.
Remedy:
- Shorten the name of the program.
- Suppress the alarm with MD 11415 $MN_SUPPRESS_ALARM_MASK_2 bit 9.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
14008
[Channel %1: ] Block %2 WRITE command writes in the temporary
memory area in /_N_EXT_DIR
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A workpiece is executed from an external data register (Execute from external drives function). The
part programs are temporarily stored in the NCK directory /_N_EXT_DIR. An attempt is now made to
write in this temporary directory with a WRITE command.
The alarm is intended to indicate that this data is not stored in the original directory on the external
data carrier, and will be lost at the next part program selection because the programs in the directory
/_N_EXT_DIR will then be deleted.
Reaction:
Alarm display.
Remedy:
State a directory that remains permanently loaded in the NCK as the target for the WRITE command
(e.g. MPF_DIR).
The alarm can be suppressed with MD11415 $MN_SUPPRESS_ALARM_MASK_2 bit 8.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
14009
[Channel %1: ] Block %2 illegal program path %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program path
Definitions:
The part program command CALLPATH was called with a parameter (program path) referring to a
directory which does not exist in the file system of the NCK.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Modify the CALLPATH instruction such that the parameter contains the complete path name of the
loaded directory.
- Load the programmed directory in the file system of the NCK.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14010
[Channel %1: ] Block %2 invalid default parameter in subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a subroutine call with parameter transfer, parameters have been omitted that cannot be replaced
by default parameters (call-by-reference parameters or parameters of type AXIS. The other missing
parameters are defaulted with the value 0 or with the unit frame in the case of frames).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The missing parameters must be provided with values in the subroutine call.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
© Siemens AG, 2009. All Rights Reserved