Overview of Alarms
NCK alarms
Remedy:
Correct NC part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10945
[Channel %1: ] Block %2 curve table %3: illegal coupling of axes
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
It is not possible to program axis links for the leading axes and following axis programmed in CTAB-
DEF.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct NC part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10946
[Channel %1: ] Block %2 curve table %3: no contour defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
No movement for the leading axis was programmed between CTABDEF and CTABEND. A curve
table is not permitted without a contour.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10947
[Channel %1: ] Block %2 curve table %3: contour not continuous
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
The contour in a curve table must be continuous. Incontinuity can occur, for example, as a result of
activating a transformation.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10948
[Channel %1: ] Block %2 curve table %3: position jump at end of period
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
A periodic curve table was defined in which the position of the following axis at the end of the table
was different to the position at the start of the table.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation: