Siemens Sinumerik 840D sl Diagnostic Manual page 205

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
Change part program and delete active tangential control with TANGDEL.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14420
[Channel %1: ] Block %2 index axis %3 frame not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
Definitions:
The axis is to be traversed as an indexing axis, but a frame is active. This is not allowed by MD32074
$MA_FRAME_OR_CORRPOS_NOTALLOWED.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program. Change MD32074
$MA_FRAME_OR_CORRPOS_NOTALLOWED.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14430
[Channel %1: ] Block %2 tangential axis %3 must not be traversed as
POS axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
A tangentially followed-up axis cannot be traversed as positioning axis.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change part program and delete active tangential control with TANGDEL.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14432
[Channel %1: ] Block %2 rounding length for tangential axis %3 is zero.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
For a tangential axis that is coupled during preparation, a rounding length must be indicated with
TANGON() on activating the tangential control, or possibly occuring discontinuities of the tangential
axis cannot be smoothed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14434
[Channel %1: ] Block %2 rel. lift-off path for tangential axis %3 is invalid
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
Factor r as programmed on TLIFT for the relative lift-off path must be within range 0 =< r < 1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation: