Siemens Sinumerik 840D sl Diagnostic Manual page 173

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
14035
[Channel %1: ] Block %2 involute: start point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the start point of the involute must be outside the basic circle. The pro-
grammed center point or radius must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14036
[Channel %1: ] Block %2 involute: end point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the end point of the involute must be outside the basic circle. The pro-
grammed center point / radius or end point must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14037
[Channel %1: ] Block %2 involute: radius invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the programmed radius of the basic circle must be greater than zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14038
[Channel %1: ] Block %2 involute not definable: end point error
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed end point does not lie on the involute defined by the start point, radius and center
point of the basic circle. The deviation of the effective end radius from the programmed value is greater
than the permissible value specified in MD21015 $MC_INVOLUTE_RADIUS_DELTA.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14039
[Channel %1: ] Block %2 involute: end point programmed several times
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, either the end point with the geometry axis identifiers or the angle of rota-
tion with AR=value can be programmed. Simultaneous programming of end point and angle of rotation
in one block is not allowed, since the end point can thus not be defined exactly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009