4012
Invalid identifier used in machine data %1[%2]
Parameters:
%1 = String: MD identifier
%2 = Index: MD array
Definitions:
The selected identifier is invalid. Valid identifiers are:
- AX1 - AXn: Machine axis identifiers
- N1AX1 - NnAXm: Link axis identifiers (NCU + machine axis), only for 'NCU-Link' expansion level!
- C1S1 - CnSm: Container axis identifiers (container + container location), only for 'Axis container'
expansion level!
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use the correct identifier.
Program Con-
Switch control OFF - ON.
tinuation:
4013
Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3
Parameters:
%1 = String: MD identifier
%2 = Index: MD array
%3 = MD value of master NCU
Definitions:
The link module configuration detected on the local NCU is different from the master NCU of the NCU
cluster. The link module configuration defines the system clock time, the communication baudrate and
the maximum number of message transfer retries.
The following machine data are used for this purpose:
- SYSCLOCK_SAMPL_TIME_RATIO,
- IPO_SYSCLOCK_TIME_RATIO,
- LINK_RETRY_CTR,
- LINK_BAUDRATE_SWITCH,
- SYSCLOCK_CYCLE_TIME
The values of these machine data must be the same on all NCUs.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
The machine data required for the link module configuration must be the same on all NCUs in the clus-
ter.
Program Con-
Switch control OFF - ON.
tinuation:
4014
Axis %1 defined several times in %2
Parameters:
%1 = String: MD identifier
%2 = String: Check and, if necessary, correct the following machine data with reference to the data
sheet:
Definitions:
An axis was assigned several times.
The axis can be a:
- Machine axis
- Link axis
- Axis in a container location
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Define a correct, unique axis assignment.
Program Con-
Switch control OFF - ON.
tinuation:
© Siemens AG, 2009. All Rights Reserved