Siemens Sinumerik 840D sl Diagnostic Manual page 253

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
16670
[Channel %1: ] Block %2 following axis/spindle %3 maximum number of
CP modules (%4) has been exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules
Definitions:
An attempt was made to activate more generic couplings than are configured in MD18450
$MN_MM_NUM_CP_MODULES.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of defined or active couplings, or increase the number of coupling modules con-
figured in MD18450 $MN_MM_NUM_CP_MODULES.
If necessary, buy another option stage of the generic coupling.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16671
[Channel %1: ] Block %2 following axis/spindle %3 maximum number of
CP modules (%4) has been exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules
Definitions:
An attempt was made to activate more generic couplings than are configured in MD18450
$MN_MM_NUM_CP_MODULES.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Reduce the number of defined or active couplings, or increase the number of coupling modules con-
figured in MD18450 $MN_MM_NUM_CP_MODULES.
If necessary, buy another option stage of the generic coupling.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
16672
[Channel %1: ] Block %2 leading axis/spindle %3 maximum number of
CP master values (%4) exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP master values
Definitions:
An attempt was made to activate more master values of generic couplings than are configured in
MD18452 $MN_MM_NUM_CP_MODUL_LEAD.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of defined or active master values, or increase the total number of master values
configured in MD18452 $MN_MM_NUM_CP_MODUL_LEAD.
If necessary, buy another option stage of the generic coupling.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-253