Siemens Sinumerik 840D sl Diagnostic Manual page 216

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
14730
[Channel %1: ] Block %2 conflict at activation of centerless
transformation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- Centerless transformation may not be activated when:
- G96 is active and regulating spindle is also master spindle.
- Regulating spindle is in interdependent grouping.
- Axes of centerless transformation overlap with an active transformation and a tool is active.
- For grinding or for regulating wheel spindle, tools are active that are not centerless tools (T1, T2).
- Constant wheel peripheral speed for the regulating spindle is active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Modify part program.
- Check tool data.
- Check machine data.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14740
[Channel %1: ] Block %2 no tool data available for centerless grinding
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
For centerless grinding, the tool data must be contained in T1, D1 (grinding wheel) or T2,D1 (regulat-
ing wheel). An error has been found here.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Modify part program.
- Check tool data.
- Check machine data.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14745
[Channel %1: ] Block %2 centerless grinding not active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt has been made to switch off the centerless grinding function even though it was not active.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14750
[Channel %1: ] Block %2 too many auxiliary functions programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
More than 10 auxiliary functions have been programmed in an NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check whether all auxiliary functions are necessary in one block - modal functions need not be
repeated. Create separate auxiliary function block or divide the auxiliary functions over several blocks.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-216
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents