230041
<location>Power unit: Undervoltage 24 V alarm
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
24 V power supply fault for the power unit.
- the 16 V threshold was undershot..
Fault value (r0949, interpret decimal):
24 V voltage [1 bit = 0.1 V].
Remedy:
Check the 24 V DC voltage supply to power unit.
230042
<location>Power unit: Fan operating time reached or exceeded
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The maximum operating time of the fan in the power unit is set in p0252.
This message indicates the following:
Fault value (r0949, interpret decimal):
0: The maximum fan operating time is 500 hours.
1: The maximum fan operating time has been exceeded.
Remedy:
Replace the fan in the power unit and reset the operating hours counter to 0 (p0251 = 0).
See also: p0251 (Operating hours counter power unit fan), p0252 (Maximum operating time power
unit fan)
230043
<location>Power unit: Overvolt 24 V
Message
-
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
The following applies for CU31x:
Overvoltage of the 24 V power supply for the power unit.
- the 31.5 V threshold was exceeded for more than 3 ms.
Fault value (r0949):
24 V voltage [1 bit = 0.1 V].
Remedy:
Check the 24 V DC voltage supply to power unit.
230044
<location>Power unit: Overvoltage 24 V alarm
Message
-
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The following applies for CU31x:
24 V power supply fault for the power unit.
- the 32.0 V threshold was exceeded.
Fault value (r0949):
24 V voltage [1 bit = 0.1 V].
Remedy:
Check the 24 V DC voltage supply to power unit.
230045
<location>Power unit: Supply undervoltage
Message
%1
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)