Cause:
It is not possible to change the DRIVE-CLiQ basic sampling times p0110 in operation. POWER ON is
required.
Fault value (r0949, interpret decimal):
Index of p0110.
Remedy:
- save (p0971 = 1).
- carry out a POWER ON.
201840
<location>SMI: Component found with changed data
Message
%1
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
Another Sensor Module Integrated (SMI) was found.
The reasons could be as follows:
1. A motor with DRIVE-CLiQ (SMI) and another order No. were used as replacement.
2. A Sensor Module Integrated was used as spare part where there is no encoder data and motor data
or the incorrect data are present.
Fault value (r0949, interpret hexadecimal):
The value should be interpreted as follows as 8-digit hexadecimal number AAAABBBB:
BBBB = Reserved.
AAAA = Component number of the component involved.
Remedy:
Re 1.
- restore the factory setting.
- carry out the first commissioning.
Re 2.
- download the SMI data from the back-up (p4690, p4691).
- carry out a POWER ON (power off/on) for all components.
201900
<location>PROFIBUS: Configuration telegram error
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
A PROFIBUS master attempts to establish a connection using an incorrect configuring telegram.
Alarm value (r2124, interpret decimal):
50: Syntax error.
51: Connection established to more drive objects than configured in the device. The drive objects for
process data exchange and their sequence were defined using p0978.
52: Too many data words for input or output to a drive object. A maximum of 16 words is permitted for
SERVO and VECTOR; and a maximum of 5 words for A_INFEED, TB30, TM31 and CU320.
53: Uneven number of bytes for input or output.
Remedy:
Check the bus configuring on the master and slave sides.
Re alarm value = 51:
Check the list of the drive objects with process data exchange (p0978). With p0978[x] = 0, all of the
following drive objects in the list are excluded from the process data exchange.
201901
<location>PROFIBUS: Parameterizing telegram error
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE