26228
[Channel %1: ] Block %2: The protection area element %3, referred to in
$NP_1ST_PROT[%4], was not found
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
%4 = Index of protection area
Definitions:
The protection area element indicated first in a protection area was not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Indicate in $NP_1ST_PROT[...] the name of an existing protection area element.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26230
[Channel %1: ] Block %2: Protection area element %3, referred to in
$NP_NEXT[%4], was not found
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
%4 = Index of protection area
Definitions:
The protection area element indicated next in a protection area was not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Indicate in $NP_NEXT[...] the name of an existing protection area element.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26231
[Channel %1: ] Block %2: The protection zone or the CAD file %3 referred
to in $TC_TP_PROTA[%4] was not found.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of tool protection zone (element)
%4 = T number of tool
Definitions:
Tool parameter $TC_TP_PROTA refers to a protection zone and a CAD file. The protection zone and
CAD file were not found.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Enter in $TC_TP_PROTA[...] the name of an existing protection zone and the name of an existing
CAD file.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
26232
[Channel %1: ] Block %2: Maximum number of %3 protection area
elements exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Name of next protection area element
Definitions:
The maximum number of permitted protection zone elements has been exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce number of protection areas or protection area elements.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
© Siemens AG, 2009. All Rights Reserved