Siemens Sinumerik 840D sl Diagnostic Manual page 617

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
120203
Communication failure
Definitions:
The operator panel is connected to the NC and PLC via a serial bus.
This alarm occurs if the MMC is started for the first time and the NC/PLC ramp-up is not yet finished
or the communication to these components is faulty.
In connection with this alarm, all display values connected with the NC/PLC become invalid.
Such faults are normal while the controls are ramping up (e.g. after resetting).
Reaction:
Alarm display.
Remedy:
The alarm disappears automatically as soon as the fault situation has ended.
If this alarm is continuously present, a wide variety of faults may be the cause. (e.g. wire breakage,
NC/PLC not ramped up, faulty address/data transfer rate configuration of one of the bus nodes, etc.).
Program Con-
Internal
tinuation:
120301
Faulty entry for hardkey 'Program' in Keys.ini.
Definitions:
The configuration in Keys.ini is wrong.
Reaction:
Alarm display.
Remedy:
In Keys.ini, the parameter ChildTask:=26 has to be set in the line KEY2.0=.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
120302
The selection is not possible. A program has to have been edited first via
the area 'Program'.
Definitions:
A program can only be selected via the hardkey program if a program has already been edited in the
program area.
Reaction:
Alarm display.
Remedy:
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program Con-
Internal
tinuation:
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
HMI-Alarms
2-617

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents