Overview of Alarms
NCK alarms
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15395
[Channel %1: ] Master-slave not executable during block search
Parameters:
%1 = Channel number
Definitions:
A master-slave coupling is to be closed in the part program via the instruction MASLON. The position
offset $P_SEARCH_MASLD, however, cannot be correctly calculated during block search, as the
axes to be coupled are located in different channels.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Make sure that all relevant axes are in the same channel.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15400
[Channel %1: ] Block %2 selected initial INIT block does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The operator has selected an INI block for a read, write or execution function which:
1. Does not exist in the NCK range or
2. Does not have the necessary protection level required for performing the function.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Check whether the selected INI block is contained in the file system of the NCK. The present protec-
tion level must be selected to be at least equal to (or greater than) the protection level that has been
defined for the read, write or execution function at the time of creating the file.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15410
[Channel %1: ] Block %2 initialization file contains invalid M function
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The only M function allowed in an Init block is the M02, M17 or M30 end-of-program function.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove all M functions from the Init block except for the end identifier.
An Init block may contain value assignments only (and global data definitions if they are not defined
again in a program that can be executed later) but no motion or synchronous actions.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
2-240
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents