03/2009
27900
PROFIBUS DP: SI fault on axis %1, code %2, value %3, time %4.
Parameters:
%1 = Axis number
%2 = Fault code of the drive (r9747).
%3 = Fault value of the drive (r9749)
%4 = Fault time of drive (r9748).
Definitions:
Error in a SINAMICS drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
27901
PROFIBUS DP: SI fault on axis %1, code %2, value %3, time %4.
Parameters:
%1 = Axis number
%2 = Fault code of the drive (r9747).
%3 = Fault value of the drive (r9749)
%4 = Fault time of drive (r9748).
Definitions:
Error in a SINAMICS drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
28000
NCU link connection to all other NCUs of the link network has been
aborted
Definitions:
All NCUs in the NCU link network exchange data cyclically (sign-of-life). If this alarm occurs, sign-of-
life signals have not been received from any other NCUs on the NCU network. This fault in the link
can have various causes:
- Defective hardware.
- The machine data which configure the NCU link are not the same on all NCUs.
- An identical interpolator cycle time has not been selected on all NCUs.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check the IPO cycle on all the NCUs.
If necessary, check NCU link-specific alarms first.
Program Con-
Switch control OFF - ON.
tinuation:
28001
NCU link connection to the NCU %1 of the link network has been aborted
Parameters:
%1 = NCU number
Definitions:
All NCUs in the NCU link network exchange data cyclically (sign-of-life). If this alarm occurs, sign-of-
life signals have not been received from one other NCU on the NCU network. (see alarm parameters)
This fault in the link can have various causes:
- Defective hardware.
- The machine data which configure the NCU link are not identical on all NCUs.
- An identical interpolator cycle time has not been selected on all NCUs.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Check the IPO cycle on all the NCUs.
- If necessary, check NCU link-specific alarms first.
Program Con-
Switch control OFF - ON.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-449