Siemens Sinumerik 840D sl Diagnostic Manual page 783

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
207596
<location>Encoder 1: Reference function interrupted
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
An activated reference function (reference mark search or measuring probe evaluation) was inter-
rupted.
- an encoder fault has occurred (Gn_ZSW.15 = 1).
- position actual value was set during an activated reference function.
- simultaneously activate reference mark search and measuring probe evaluation (BI: p2508 and BI:
p2509 = 1 signal).
- activated reference function (reference mark search or measuring probe evaluation) was de-acti-
vated (BI: p2508 and BI: p2509 = 0 signal).
Remedy:
- check the causes and resolve.
- reset the control (BI: p2508 and BI: p2509 = 0 signal) and activate the requested function.
207597
<location>Encoder 2: Reference function interrupted
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
An activated reference function (reference mark search or measuring probe evaluation) was inter-
rupted.
- an encoder fault has occurred (Gn_ZSW.15 = 1).
- position actual value was set during an activated reference function.
- simultaneously activate reference mark search and measuring probe evaluation (BI: p2508 and BI:
p2509 = 1 signal).
- activated reference function (reference mark search or measuring probe evaluation) was de-acti-
vated (BI: p2508 and BI: p2509 = 0 signal).
Remedy:
- check the causes and resolve.
- reset the control (BI: p2508 and BI: p2509 = 0 signal) and activate the requested function.
207598
<location>Encoder 3: Reference function interrupted
Message
-
value:
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
An activated reference function (reference mark search or measuring probe evaluation) was inter-
rupted.
- an encoder fault has occurred (Gn_ZSW.15 = 1).
- position actual value was set during an activated reference function.
- simultaneously activate reference mark search and measuring probe evaluation (BI: p2508 and BI:
p2509 = 1 signal).
- activated reference function (reference mark search or measuring probe evaluation) was de-acti-
vated (BI: p2508 and BI: p2509 = 0 signal).
Remedy:
- check the causes and resolve.
- reset the control (BI: p2508 and BI: p2509 = 0 signal) and activate the requested function.
207599
<location>Encoder 1: Adjustment not possible
Message
Drive data set: %1
value:
Drive object:
SERVO, VECTOR
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
SINAMICS-Alarms
2-783